Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(7)2023 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-37050727

RESUMO

This paper describes the design steps carried out to prove the concept of a wideband monopole antenna system to be used in a wearable device conceived for the evaluation of electromagnetic field radiation. Such a device is envisaged to be integrated into protective vests worn by professional users in their working space environment as part of intelligent multi-risk protection. Initially, the main characteristics of a simple straight monopole are reviewed to serve as a reference. A modified octagonal monopole antenna element is introduced, and a two dual-linearly polarized configuration of such monopoles is designed, fabricated, and tested to be used in the frequency range of 0.7-3.5 GHz. The expected radiation characteristics (input reflection coefficient and isolation between vertically and horizontally polarized ports) are confirmed experimentally. The effects of a thick lossy foam substrate layer used to mitigate the presence of the metal shield, employed in the vest lining as a Faraday cage protection, are analyzed both by simulation and experimentally. Finally, electromagnetic simulations are carried out to confirm that a system of five dual-linearly polarized monopole elements located in the chest, shoulders, back, and helmet of the user can provide an adequate estimation of the incident electromagnetic field radiation.

2.
Phys Med ; 104: 160-166, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36463580

RESUMO

PURPOSE: Patient-specific information on the depth of Axillary Lymph Nodes (ALNs) is important for the development of new diagnostic imaging technologies, e.g. Microwave Imaging (MWI), aiming to assess the diagnosis of ALNs during breast cancer staging. Studies about ALNs depth have been presented for treatment planning, but they lack information on sample size and usability of the data to infer the depth of ALNs. The aim of this study was to create a mathematical model that can be used to predict a depth interval where level I ALNs are likely to be located. METHODS: We extracted biometric features of 98 patients who underwent breast Magnetic Resonance Imaging (MRI) to train two types of regression models. We then tested different combination of features to predict ALNs depth and found the best predictor. The final prediction models were then implemented in an algorithm used for MWI and tested with anthropomorphic phantoms of the axillary region. RESULTS: Body Mass Index (BMI) was the feature with best performance to predict ALNs depth with coefficient of determination (R2) ranging from 0.49 to 0.55 and Root Mean Squared Error (RMSE) ranging from 0.68 to 0.91 cm. The proposed model showed satisfactory results in microwave images of patients with different BMIs. CONCLUSIONS: The presented results contribute to the development of reconstruction algorithms for new imaging technologies and to the assessment of ALNs in other medical applications.


Assuntos
Imageamento de Micro-Ondas , Humanos
3.
Med Phys ; 48(10): 5974-5990, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34338335

RESUMO

PURPOSE: Microwave imaging (MWI) has been studied as a complementary imaging modality to improve sensitivity and specificity of diagnosis of axillary lymph nodes (ALNs), which can be metastasized by breast cancer. The feasibility of such a system is based on the dielectric contrast between healthy and metastasized ALNs. However, reliable information such as anatomically realistic numerical models and matching dielectric properties of the axillary region and ALNs, which are crucial to develop MWI systems, are still limited in the literature. The purpose of this work is to develop a methodology to infer dielectric properties of structures from magnetic resonance imaging (MRI), in particular, ALNs. We further use this methodology, which is tailored for structures farther away from MR coils, to create MRI-based numerical models of the axillary region and share them with the scientific community, through an open-access repository. METHODS: We use a dataset of breast MRI scans of 40 patients, 15 of them with metastasized ALNs. We apply image processing techniques to minimize the artifacts in MR images and segment the tissues of interest. The background, lung cavity, and skin are segmented using thresholding techniques and the remaining tissues are segmented using a K-means clustering algorithm. The ALNs are segmented combining the clustering results of two MRI sequences. The performance of this methodology was evaluated using qualitative criteria. We then apply a piecewise linear interpolation between voxel signal intensities and known dielectric properties, which allow us to create dielectric property maps within an MRI and consequently infer ALN properties. Finally, we compare healthy and metastasized ALN dielectric properties within and between patients, and we create an open-access repository of numerical axillary region numerical models which can be used for electromagnetic simulations. RESULTS: The proposed methodology allowed creating anatomically realistic models of the axillary region, segmenting 80 ALNs and analyzing the corresponding dielectric properties. The estimated relative permittivity of those ALNs ranged from 16.6 to 49.3 at 5 GHz. We observe there is a high variability of dielectric properties of ALNs, which can be mainly related to the ALN size and, consequently, its composition. We verified an average dielectric contrast of 29% between healthy and metastasized ALNs. Our repository comprises 10 numerical models of the axillary region, from five patients, with variable number of metastasized ALNs and body mass index. CONCLUSIONS: The observed contrast between healthy and metastasized ALNs is a good indicator for the feasibility of a MWI system aiming to diagnose ALNs. This paper presents new contributions regarding anatomical modeling and dielectric properties' characterization, in particular for axillary region applications.


Assuntos
Neoplasias da Mama , Imageamento de Micro-Ondas , Axila/diagnóstico por imagem , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Linfonodos/diagnóstico por imagem , Imageamento por Ressonância Magnética
4.
Annu Int Conf IEEE Eng Med Biol Soc ; 2020: 1787-1790, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-33018345

RESUMO

Medical Microwave Imaging (MWI) has been studied as a technique to aid breast cancer diagnosis. Several different prototypes have been proposed but most of them require the use of a coupling medium between the antennas and the breast, in order to reduce skin backscattering and avoid refraction effects. The use of dry setups has been addressed and recent publications show promising results. In this paper, we assess the importance of considering refraction effects in the image reconstruction algorithms. To this end, we consider a simplified homogeneous spherical model of the breast and analytically compute the propagating rays through the air-body interface. The comparison of results considering only direct ray propagation or refracted rays shows negligible impact on the accuracy of the images for moderately high permittivity media. Thus, we may avoid the computational burden of calculating the refracted rays in convex shapes.


Assuntos
Neoplasias da Mama , Micro-Ondas , Algoritmos , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador
5.
Sensors (Basel) ; 20(17)2020 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-32887340

RESUMO

We produced an anatomically and dielectrically realistic phantom of the axillary region to enable the experimental assessment of Axillary Lymph Node (ALN) imaging using microwave imaging technology. We segmented a thoracic Computed Tomography (CT) scan and created a computer-aided designed file containing the anatomical configuration of the axillary region. The phantom comprises five 3D-printed parts representing the main tissues of interest of the axillary region for the purpose of microwave imaging: fat, muscle, bone, ALNs, and lung. The phantom allows the experimental assessment of multiple anatomical configurations, by including ALNs of different size, shape, and number in several locations. Except for the bone mimicking organ, which is made of solid conductive polymer, we 3D-printed cavities to represent the fat, muscle, ALN, and lung and filled them with appropriate tissue-mimicking liquids. Existing studies about complex permittivity of ALNs have reported limitations. To address these, we measured the complex permittivity of both human and animal lymph nodes using the standard open-ended coaxial-probe technique, over the 0.5 GHz-8.5 GHz frequency band, thus extending current knowledge on dielectric properties of ALNs. Lastly, we numerically evaluated the effect of the polymer which constitutes the cavities of the phantom and compared it to the realistic axillary region. The results showed a maximum difference of 7 dB at 4 GHz in the electric field magnitude coupled to the tissues and a maximum of 10 dB difference in the ALN response. Our results showed that the phantom is a good representation of the axillary region and a viable tool for pre-clinical assessment of microwave imaging technology.


Assuntos
Neoplasias da Mama , Imageamento de Micro-Ondas , Imagens de Fantasmas , Axila , Neoplasias da Mama/diagnóstico por imagem , Humanos , Linfonodos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...